Brand Name : | PEAK INSTRUMENTS |
Model Number : | AA3014 |
Price : | $15,000.00/units >=1 units |
Product Name | Single Beam Graphite furnace Atomic Absorption Spectrometer |
Origin | China |
Brand | PEAK INSTRUMENTS |
Model | AA3014 |
Wavelength range | 190-900nm |
Grating | Holographic diffraction grating with 1800 lines/mm |
Monochromator | Czerny-Turner type with focal lengths at 350mm |
Detector | UV Sensitive Photomultiplier Tube |
Slits | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm |
Lamp Holder | Automated 8-Lamp Turret |
Photometric Range | 0-125%, -0.1-3.00A |
Reading Mode | Transmittance, Absorbance, Concentration |
Back Ground Correction | Deterium (D2) Lamp Back Ground Correction |
Software | RGWIN AAS software |
Power Supply | 110/220V, 50/60Hz |
Packing Dimension | 101*78*83cm, 128kgs. |
Quality | 1. Our products have good quality and very positive reputations in
the market. 2. Customers are very happy with them and have a lot of good
comments about our intruments and service. | |
Delivery Time | 1. We can get them ready 3-5 days after order confirmation for
small orders. 2. For big quantities, need to be confirmed. 3. In most cases, fast delivery is guaranteed. | |
Technical Support | 1. We have service manual. If not, detailed documents or videos
will be provided. 2. We can provide online or site training in our factory. 3. We can have video conference at any time. | |
Aftersales Support | 1. Respond to your questions within 10 minutes during our working
time from 6:30 to 24:00, at most within 8 hours after 24:00
considering the time difference. 2. Within warranty, we will solve the problem for you with no
charge(except for consumables). 3. You can call, text or email us at any time. We have good English
speakers. | |
Warranty Time | One year and extendable | |
Our product advantages are as follws: |
Q: What areas and applications can it be used? | ||||||||
A: It can be used for qualitative or quantitative meansurements for
water solution in the following areas: metallurgy, pharmacy, food,
health, institutes, biological chemistry, life science,
petrochemical industry, mining, quality control, environmental
protection, etc. | ||||||||
Q: Does it need any installation | ||||||||
A: The installation is very simple, just need to connect it to
power supply and turn it on, then you can use it. | ||||||||
Q: What standard accessories are included? | ||||||||
A: Main unit, 1cm cell holder(4 positions for single beam and 2
positions for double beam), 4 pcs of 1cm glass cuvette(all models)
and 2 pcs of 1 cm quartz cuvette(UV models), one USB with user
manual and power cable. | ||||||||
Q: Is PC software included? | ||||||||
A: The PC software(CFR 21 or regular one) is optional. Also the
thermal printer is available on requested. | ||||||||
Q: Why the reading is red and reach its maximum value 3.00Abs? | ||||||||
A: Probably you use the glass cuvette in UV range. | ||||||||
Q: Why the wavelength calibration or self checking fail? | ||||||||
A: The deuterium lamp is turned off or there is something wrong
with the D2 lamp, like the fuse, triode or the lamp itself. | ||||||||
Q: Why is the reading is not as accurate as before? | ||||||||
A: Do the wavelength calibration before testing or restore the
device to its default factory settings. | ||||||||
Q: Why PC software can not be installed successfully? | ||||||||
A: Close your anti-virus software on the computer and do it again. | ||||||||
Q: Why the software can not be connected successfully? | ||||||||
A: Please return to its initial interface and don't enter any menu
when connecting to PC software. And the device can not be operated
once connected to software. Secondly, unload the previous/old
version PC software if there is. | ||||||||
Q: Can the data transferred to USB or PC? | ||||||||
A: Yes, you can transfer the saved data on the device to a USB then
copy it to PC, or you can save the data directly on the PC via
software. | ||||||||
Q: Why the Abs value is negative(lower than zero). | ||||||||
A: Do the blanking or change the reference sample. |
![]() |