Brand Name : | PEAK INSTRUMENTS |
Model Number : | AA2914 |
Price : | $6,272.00 - $10,452.00/units |
Model | AA2914 | AA2918 | AA2928 | |||
Optical System | Optical Type | Single beam | Single beam | Double beam | ||
Monochromator | Czerny-Turner type with focal lengths at 350mm | |||||
Wavelength Range | 190-900nm | |||||
Grating | Holographic diffraction grating with 1800 lines/mm | |||||
Slits | Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm | |||||
Wavelength Accuracy | ±0.3 nm | ±0.2 nm | ±0.15 nm | |||
Wavelength Repeatability | ±0.1nm | ±0.1nm | ±0.05nm | |||
Lamp Holder | Automated 4-lamp turret | Automated 8-lamp turret | ||||
Detector | Wide range UV sensitive photomultiplier tube | |||||
Photometric Performance | Reading Mode | Transmittance(T), Absorbance(A), Concentration(C) | ||||
Photometric Range | 0-125%, -0.1-3.00A | |||||
Static Baseline Drift (Cu) | ≤0.004A/30 min | ≤0.003A/30 min | ≤0.002A/30 min | |||
Dynamic Baseline Drift (Cu) | ≤0.006A/15 min | ≤0.005A/15 min | ≤0.004A/15 min | |||
Background Correction | Deuterium (D2) Background Correction | D2 and Self-absorption | ||||
Flame Analysis | Characteristic Concentration | Cu≤0.04ug/ml | Cu≤0.035ug/ml | Cu≤0.035ug/ml | ||
Detection Limit | Cu≤0.008ug/ml | Cu≤0.006ug/ml | Cu≤0.004ug/ml | |||
Repeatability (Cu) | RSD≤1% | RSD≤0.6% | RSD≤0.5% | |||
Acetylene Flow Control | Auto 12-level | Auto 12-level | Auto 12-level | |||
Air Flow Control | Auto 4-level | Auto 4-level | Auto 4-level | |||
Nebulizer | High efficiency glass | |||||
Burner Adjustment | Automatic up and down | |||||
Burner Head | Titanium alloy 100mm burner for air/acetylene operation | |||||
Premix Chamber | Corrosion resistant | |||||
Safety Protection | Flame sensor, gas leak sensor, gas pressure sensor | |||||
Data Processing | Software | RGWIN AAS software pacakage | ||||
Analytical Method | Flame AA, Flame AE, Hydride Generation | |||||
Concentration Calculation Method | Standard curve(6 linear/non-linear fitting), Standard Addition,
Interpolation | |||||
Repeated Measurement Times | 1-30 times, calculate the average, show SD and RSD value of
absorbance and concentration | |||||
QA/QC Function | Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of
concentration | |||||
Report Printing | Parameter printing, resulting printing | |||||
Communication Port | Standard RS-232 | |||||
Others | Computer | External(excluded) | ||||
Dimension & Weight | 850*650*550MM(W*D*H), 100Kg | |||||
Power Supply | 110/220V, 50/60Hz | |||||
Working Environment | Temperature 10 ~ 35 °C, Humidity≦85% |
NO. | Description | Qty | NO. | Description | Qty |
1 | Main Unit | 1 | 8 | 6mm air tube(transparent) | 10m |
2 | Power Cable | 1 | 9 | USB(manual and software) | 1 |
3 | Data Cable | 1 | 10 | Drain Tube | 2m |
4 | Screw Driver | 1 | 11 | Acetylene pressure reducing valve connector | 1 |
5 | Cu HCL | 1 | 12 | 5A fuse | 3 |
6 | Air Compressor | 1 | 13 | Ignition filament | 5 |
7 | 6mm acetylene tube(orange) | 10m |
Quality | 1. Our products have good quality and very positive reputations in
the market. 2. Customers are very happy with them and have a lot of good
comments about our intruments and service. | |
Delivery Time | 1. We can get them ready 3-5 days after order confirmation for
small orders. 2. For big quantities, need to be confirmed. 3. In most cases, fast delivery is guaranteed. | |
Technical Support | 1. We have service manual. If not, detailed documents or videos
will be provided. 2. We can provide online or site training in our factory. 3. We can have video conference at any time. | |
Aftersales Support | 1. Respond to your questions within 10 minutes during our working
time from 6:30 to 24:00, at most within 8 hours after 24:00
considering the time difference. 2. Within warranty, we will solve the problem for you with no
charge(except for consumables). 3. You can call, text or email us at any time. We have good English
speakers. | |
Warranty Time | One year and extendable | |
Our product advantages are as follws: |
Q: What areas and applications can it be used? | ||||||||
A: It can be used for qualitative or quantitative meansurements for
water solution in the following areas: metallurgy, pharmacy, food,
health, institutes, biological chemistry, life science,
petrochemical industry, mining, quality control, environmental
protection, etc. | ||||||||
Q: Does it need any installation | ||||||||
A: The installation is very simple, just need to connect it to
power supply and turn it on, then you can use it. | ||||||||
Q: What standard accessories are included? | ||||||||
A: Main unit, 1cm cell holder(4 positions for single beam and 2
positions for double beam), 4 pcs of 1cm glass cuvette(all models)
and 2 pcs of 1 cm quartz cuvette(UV models), one USB with user
manual and power cable. | ||||||||
Q: Is PC software included? | ||||||||
A: The PC software(CFR 21 or regular one) is optional. Also the
thermal printer is available on requested. | ||||||||
Q: Why the reading is red and reach its maximum value 3.00Abs? | ||||||||
A: Probably you use the glass cuvette in UV range. | ||||||||
Q: Why the wavelength calibration or self checking fail? | ||||||||
A: The deuterium lamp is turned off or there is something wrong
with the D2 lamp, like the fuse, triode or the lamp itself. | ||||||||
Q: Why is the reading is not as accurate as before? | ||||||||
A: Do the wavelength calibration before testing or restore the
device to its default factory settings. | ||||||||
Q: Why PC software can not be installed successfully? | ||||||||
A: Close your anti-virus software on the computer and do it again. | ||||||||
Q: Why the software can not be connected successfully? | ||||||||
A: Please return to its initial interface and don't enter any menu
when connecting to PC software. And the device can not be operated
once connected to software. Secondly, unload the previous/old
version PC software if there is. | ||||||||
Q: Can the data transferred to USB or PC? | ||||||||
A: Yes, you can transfer the saved data on the device to a USB then
copy it to PC, or you can save the data directly on the PC via
software. | ||||||||
Q: Why the Abs value is negative(lower than zero). | ||||||||
A: Do the blanking or change the reference sample. |
![]() |